• Product
    • Product
    • Supplier
Advanced

Industrial 10G 19" Rack-mount Ethernet Switch

Supplier
LANTECH COMMUNICATIONS GLOBAL, INC
Request for Quotation

4- Modular-Slots w/2 10GT uplink + 4/2 x1G/2.5G/10G SFP+

Spec

  • Communication Mode : Full-Duplex
  • Function : LACP,POE,QoS,SNMP,Stackable,VLAN Support
  • Products Status : Stock

Key Features

Lantech I(P)GS-6300-2P is a high performance L2+ (All Gigabit) modular Ethernet switch with max 24/26port Gigabit + 4/2 1G/2.5G/10G SFP+ + 2 10GT uplink (total 28ports) w/(24 PoE 802.3af/at Injectors) which provides L2+ wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring. It also supports train mode, enhanced mode with easy configuration, comprehensive QoS, QoS by VLAN**, advanced security including INGRESS/EGRESS ACL L2/L3, TACACS+, SSH/SSL, Mac based DHCP server, DHCP Option 82/66*, DHCP server, IGMPv1/v2/v3/router port, QinQ**, QoS QinQ** which are important features required in large network. The Cisco Discovery Protocol (CDP) and LLDP are supported for Ciscoworks to detect the switch info and show on L2 map topology. The enhanced platform allows quick booting up time under 50 seconds.

Up to 24 PoE at/af ports w/advanced PoE management 
Compliant with 802.3af/at standard, the Lantech I(P)GS-6300-2P is able to feed each PoE port up to 30 Watt. Lantech I(P)GS-6300-2P supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE port can be enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.

Miss-wiring avoidance, Repowered auto ring* restore, Loop protection
The I(P)GS-6300-2P also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech I(P)GS-6300-2P is able to alert with the LED indicator and disable ring automatically. Repowered auto ring* restore function (node failure protection) ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.

DHCP option 82 & Port based, Mac based DHCP, Option66*, IPv6 DHCP server**
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Option66 server can offer IP address of TFTP server to DHCP client for VOIP application. Optional IPv6 address resolution for DHCP service can be supported.

User friendly GUI, Auto topology drawing, FX dB value
The user friendly UI, innovative auto topology drawing and topology demo makes I(P)GS-6300-2P much easier to get hands-on. The I(P)GS-6300-2P supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power, temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer, making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.

Enhanced G.8032 ring, 8/16* MSTI MSTP; Optional MRP ring
Lantech I(P)GS-6300-2P features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring*, basic ring, multiple-VLAN ring* and auto-ring* by easy setup than others. The innovative auto-Ring* configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows each spanning tree for each VLAN for redundant links with 8/16* MSTI.
Optional MRP (Media Redundancy Protocol) can be supported for industrial automation networks.

QoS by VLAN** for legacy device
QoS by VLAN** can allow switch to tag QoS by VLAN** regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.

QinQ**, QoS QinQ** and GVRP supported
It supports the QinQ**, QoS QinQ**, GVRP for large VLAN segmentation.

IGMPv3, GMRP, router port, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port and static multicast forwarding binding by ports for video surveillance application.

Editable configuration file
The configuration file of Lantech I(P)GS-6300-2P can be exported and edited with word processor for the other switches configuration with ease. The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead. I(P)GS-6300-2P also supports dual image firmware function*.
The built-in USB slot can upload/download the firmware through USB dongle for switch replacement.

Event log & message; 2 DI + 2DO
In case of event, the I(P)GS-6300-2P is able to send an email & SMS** text message to pre-defined addresses as well as SNMP Traps out immediately. It provides 2DI and 2DO. When disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.

Environmental monitoring for switch inside information 
The environmental monitoring can detect switch overall temperature, (total PoE load), voltage and current where can send the SNMP traps, email and SMS** alert when abnormal.

Dual power DC/LDC/HV/AC input and dedicated PoE power source input 
Lantech I(P)GS-6300-2P chassis and modules are designed for easy maintenance and installation; It also supports dual DC/LDC power supplies (DC12~48V/ isolated 36~75VDC), dual HV (isolated 85~264VAC/100~370VDC) or dual AC(85~264VAC) input to increase the network reliability. It has independent PoE power source input by terminal block for connecting DC 48V PoE power source. (IPGS-6300-2P)

Industrial hardened design with high EFT/SURGE and ESD CONTACT protection
Lantech I(P)GS-6300-2P features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. Featured with relay contact alarm function, the I(P)GS-6300-2P is able to connect with alarm system in case of power failure or port disconnection. The I(P)GS-6300-2P also provides 2000V EFT/SURGE and 6000V ESD CONTACT protection, which can reduce unstable situation caused by power line and Ethernet.
It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory applications. The -E model can be used in extreme environments with an operating temperature range of -40°C to 75°C.
*Future Release
**Optional
***Optional DDM SFP required

Last Update : 2019-04-08
LoadingLoading ...


The purpose of Slider Kit is to gather common slideshow-like jQuery functionalities (such as news sliders, photos galleries/sliders, carousels, tabs menus)

When tracking mouse movement, you usually need to know the actual position of the mouse pointer. The event object that is passed to the handler contains some information about the mouse coordinates.

Step 1Fill in the formStep 2Completion

Mr.Greg Tsai , LANTECH COMMUNICATIONS GLOBAL, INC

Use ";" or "," to separate multiple recipients.

USD
Insert a template
0/1500

File formats: htm, html, doc, docx, pdf, txt, jpg, gif, png. Max 3 files (10MB in total).

Total size:0

  • +

This helps to more precisely match your inquiry with potential suppliers.Use "," or "enter" to separate multiple keywords.

Please fill in all required fields.

    Recommendations

    Loading ...

    Small Order Recommendation

    Loading ...